Product Description
Features
- Measuring the mass flow or volume flow of gas
- Do not need to do temperature and pressure compensation in principle with accurate measurement and easy operation.
- Wide range: 0.5Nm~100Nm/s for gas. The meter also can be used for gas leak detection
- Good vibration resistance and long service life. No moving parts and pressure sensor in transducer, no vibration influence on the measurement accuracy.
- Easy installation and maintenance. If the conditions on site are permissible, the meter can achieve a hot-tapped installation and maintenance. (Special order of custom-made)
- Digital design, high accuracy and stability
- Configuring with RS485 or HART interface to realize factory automation and integration
Specifications:
- Measuring Medium: Various gases (Except the acetylene)
- Pipe Size: DN10~DN4000mm
- Velocity: 0.1~100 Nm/
- Accuracy: ±1~2.5%
- Working Temperature: Sensor: -40~+220 degree, Transmitter: -20~+45 degree
Working Pressure:- Insertion Sensor: medium pressure less than 1.6MPa
- Flanged Sensor: medium pressure less than 1.6MPa
Power Supply:
- 1) Compact type: 24VDC or 220VAC, Power consumption less than 18W
- 2) Remote type: 220VAC, Power consumption less than 19W
Response Time: 1s
Output: 4-20mA (optoelectronic isolation, maximum load 500 Ohms), Pulse, RS485 (optoelectronic isolation) and HART
Alarm Output: 1-2 line Relay, Normally Open state, 10A/220V/AC or 5A/30V/DC
Sensor Type: Standard Insertion, Hot-tapped Insertion and Flanged
Construction: Compact and Remote
Pipe Material: Carbon steel, stainless steel, plastic, etc
Display: 4 lines LCD, Mass flow, Volume flow in standard condition, Flow totalizer, Date and Time, Working time, and Velocity, etc.
Protection Class: IP65
Sensor Housing Material: Stainless steel (316)